Current
Sensors |
MI-3240-CTS |
|
| |
AC
Current Sensors-MI-3200-SC200 |
|
|
| |
Microcomm's AC Current Sensors series MI-3200-SC200
Connect directly to any Data Logger input channel.
Also connects directly to any recorder or data
acquisition system that has a 0-5vdc input.
No external power required. Split core construction
simplifies installation on existing conductor.
Nylon thumb screws, no exposed metal parts;
Monitor motors, pumps, or any AC load.
|
|
|
| Features: |
- Split core design
- Self powered
- Rugged plastic housing
- Output signal is accurate
even at very low input current levels (below
1% of full scale).
|
| Technical
Specifications: |
|
◊ |
Input Current |
- |
AC Current,
single phase, 50 - 400 Hz, load power factor 0.5
to 1.0 lead or lag. |
|
◊ |
Accuracy |
- |
±2.0%
of reading from 2.5 % to 100% of full scale.
±4% of reading at 1% of full scale. |
|
◊ |
Bandwidth |
- |
10-1000Hz
(within ±3db) |
|
◊ |
Temperature
Effect |
- |
±0.05%
(-20 to 85°C) |
|
◊ |
Response
time |
- |
250 milliseconds
(input from 10% to 90% of full scale). |
|
◊ |
Ripple |
- |
0.5% |
|
◊ |
Voltage rating |
- |
600 Vac.
Tested with full wave 10KV impulse for 60 seconds. |
|
◊ |
Overload |
- |
1.6x full
scale (continuous). |
|
◊ |
Surge |
- |
3x full scale. |
|
◊ |
Lead wires |
- |
8 ft (2.4
meter) signal cable. |
|
◊ |
Output signal |
- |
Linear 0
- 5vdc |
|
◊ |
Low range usability |
|
To below
0.1% of full scale. |
◊ |
Overall size |
|
Add
2" to Window size in table below for overall
length and height dimension (Add 2.5" for
SC1500A).
Overall width 1.25" (includes nylon thumbscrews)
|
|
| |
AC
Current Sensors-MI-3200-DC100A |
|
|
| |
Microcomm's AC Current Sensors series MI-3200-DC100A
Connect directly to any Data Logger input channel.
No external power required. Also connects directly
to any recorder or data acquisition system with
a 0-5vdc input and 5vdc excitation.
|
|
|
| Features: |
- Single 5vdc supply, consumes
less than 10ma
- Self powered
- Rugged plastic housing
- Output signal is accurate
even at very low input current levels (below
1% of full scale).
|
| Technical
Specifications: |
|
◊ |
Total output error |
- |
±1%
of full scale at 25°C
|
|
◊ |
Range |
±50
amps dc |
◊ |
Zero offset |
- |
±0.15%
of F.S. maximum (-40 to 80°C) |
|
◊ |
Temperature effect on
span |
- |
±0.10%
of F.S. per °C |
|
◊ |
Response time |
- |
2 milliseconds
(dc current change from 10% to 90% of full scale). |
|
◊ |
Isolation voltage |
- |
3kVRMS minimum
(current terminals to signal cable lead wires) |
|
◊ |
Surge rating (all models) |
- |
300 amps
for 10 second pulse, 10% maximum duty cycle for
repetitive pulses.
800 amps for 1 second pulse, 1% maximum duty cycle
for repetitive pulses.
|
|
◊ |
Continuous over current
(all models) |
- |
180 amps |
|
◊ |
Power requirements |
- |
5vdc (±10%),
10ma max |
|
◊ |
Output signal vs supply
voltage |
- |
Output signal
ratiometric to supply voltage |
|
◊ |
Warm-up time |
- |
10 milliseconds
(time from power applied until output signal is
valid). |
|
◊ |
Output signal |
- |
Linear 0.5
- 4.5vdc (0 amps = 2.5v) |
|
◊ |
Signal cable leads |
|
Four: Ground,
+5v supply, Signal output, Shield drain wire. (shield
drain wire has no internal connection inside sensor). |
◊ |
Signal cable length |
|
10
ft (3 meter)
|
◊ |
Operating
temperature range |
|
-40°C
to 80°C (-40°F to 176°F) |
|
◊ |
Overall size |
|
3.50"
long, 2.55" wide, 1.25" high
89mm x 65mm x 32mm high |
◊ |
DC current terminals |
|
Two 1/4-20
aluminum studs, with nuts and lock washers. Suitable
for ring terminals (ring terminals not supplied). |
◊ |
Mounting holes |
|
Two
0.19"dia. holes, 3.0" O.C. |
|
| |
|
|